COMPRESSOR
We have the same compressor provided by Thomas Industries that we’ve had over the last few years. The compressor will put out approximately 120psi before the relief valve opens. Because the compressor can produce a significant amount of vibration, we have included vibration isolation mounts donated by the Lord Corporation. They can be screwed directly into the feet of the compressor as shown on the following picture. In order for these to isolate the vibration, they need to be mounted to a stiff piece of metal such as a 1/4” aluminum plate. The distance between the front feet is 3.5”. The distance from the centerline of these feet to the rear foot is 5.19”. A spike relay should be used to control the power to the compressor using a 20amp breaker, not a fuse. Ensure that the relay is programmed to provide “forward” power only to the compressor. Do not reverse the compressor! Norgren has supplied the pressure relief valve. It is shown installed on the compressor.